Ninhydrin Coloring Solution Kit-Ⅱ for JEOL

for JEOL-Amino Acid Automated Analyzer
Manufacturer :
FUJIFILM Wako Pure Chemical Corporation
Storage Condition :
Keep below 25 degrees C.
GHS :
  • Structural Formula
  • Label
  • Packing
SDS
Comparison
Product Number
Package Size
Price
Inventory
Distributor
295-70601
Barcode No
4987481610729
2L
List Price
165.00 USD

In stock in Japan

Document

SDS
Product Specification Sheet
Spectral Data
Certificate of Analysis
Calibration Certificate

Ninhydrin Color Development Method

Ninhydrin reaction is a method to detect and quantify amino acids via ninhydrin coloration.

00434_img01.png

Amino acids reacted with ninhydrin reaction reagent are detected using two wavelengths, i.e., 570 nm and 440 nm.
The primary amine amino acid (α-amino acid) is colored purple at 570 nm, while the secondary amine (imino acid) amino acid is colored yellow at 440 nm.

Protocol

Methods for amino acid analysis include precolumn derivatization and postcolumn derivatization employed by ninhydrin. Postcolumn derivatization is a method in which a sample is reacted with the derivatization reagent after column separation and transferred to the detector.

00434_img02.png
Flow diagram of ninhydrin method1)
Measurement Principle
  1. The sample is pressured into an alkaline-cation exchange resin. When the eluent pH is increased in a stepwise manner, a higher amount of acidic amino acid is eluted early.
  2. When this eluate is heated after the addition of Ninhydrin Coloring Solution, a colored substance showing the local maximum absorption is produced at 570 nm for α-amino acid and 440 nm for imino acid.
  3. The peak area of this colored substance is compared with that of the standard solution to determine the concentration of each amino acid in the sample.
  1. Ito, M. et al. : Wako Jun-yaku Jiho, 86 (3), 15 (2018).

Amino Acid Automated Analyzer Manufactured by JEOL: JLC-500/V

00434_img04.png

Features

  • It provides highly accurate and reproducible data
    Highly accurate and reproducible data can be obtained due to technologies, such as vacuum degasser to remove dissolved gas in buffer solution, pump with constant-flow sensor feedback, phase-control pulse mixing type that can efficiently mix ninhydrin and eluent.
  • It employs a tandem column
    It employs a tandem column (multi-stage laminated pressure dispersion column) that prevents the resin from crushing and clogging owing to high pressure and high speed, and this extends the column service life.
  • It is compatible with GLP
    Software installed includes those for equipment performance validation (instrument, analytical method); system suitability test during routine analysis; equipment maintenance; analytical method change; and performance check.

Manufacturer's Website: JEOL Website

Overview / Applications

Property

Manufacturer Information

Alias

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.

877-714-1920

Hours of Operation: 8:00 - 17:00 (EST)For other hours than the above, please contact us via the inquiry form.