It has been added to the cart.

It has been added to the comparison table.

MagCapture™ EV Isolation Kit PS for HTS

for Genetic Research
Manufacturer :
FUJIFILM Wako Pure Chemical Corporation
Storage Condition :
Keep at 2-10 degrees C.
GHS :
  • Label
SDS
Comparison
Product Number
Package Size
Price
Availability
Certificate of Analysis
Purchase
Distributor
293-96401
Barcode No
4548995099587
96Tests
List Price
3,300.00 USD

In stock in Japan

Document

SDS
Certificate of Analysis

Kit component

Kit content

EV Capture Magnetic Beads 5.8 mL
EV Washing Buffer (10x) 90 mL
EV Binding Enhancer (500x) 3 mL
EV Elution Buffer (10x) 3 mL

Product Overview

The MagCapture™ EV Isolation Kit PS for HTS, utilizing the PS affinity method, is designed for the isolation and purification of extracellular vesicles (EVs) for use with automated extraction devices, such as the KingFisher™ Flex (Thermo Fisher Scientific Inc.). It enables the isolation and purification of EVs, including exosomes, from up to 96 samples at once, making it highly suitable for biomarker discovery and high-throughput screening (HTS) applications in EV research.

About commercial or for-profit purposes

Please use this product for research purposes only. If you wish to use it for commercial or for-profit purposes, please contact Fujifilm Wako at wkuslabchem@fujifilm.com.

Features

  • Using an automated extraction device, this kit allows the isolation and purification of EVs from up to 96 samples simultaneously.
  • Enables the isolation of high-purity EVs with minimal damage.

Comparison with manual kit (MagCapture™ Exosome Isolation Kit PS Ver.2)

Compared to the MagCapture™ Exosome Isolation Kit PS Ver.2 (Product No. 290-84103), which is designed for manual isolation and purification, this kit differs in the following respects. Note that the EV recovery efficiency is comparable (see “Performance Data” for details).

Automated extraction
(MagCapture™ EV Isolation Kit PS for HTS)
Manual extraction
(MagCapture™ Exosome Isolation Kit PS Ver.2)
Method by which Tim4 binds to magnetic beads Directly prebound: Tim4 is already bound to the magnetic beads, eliminating the need for a separate binding step. Avidin-biotin mediated: Tim4 binds to magnetic beads through the avidin-biotin interaction, requiring an additional step for Tim4 binding.
Detergent concentration in the elution buffer High: To minimize the loss of magnetic beads. Low
EDTA concentration in the elution buffer High: To reduce the number of elution steps. Low

Samples (example)

  • Cell Culture Supernatant
  • Serum
  • Plasma
  • Urine
  • Saliva

Compatible automated extraction devices
(with proven isolation performance)

  • KingFisher™ Flex (Thermo Fisher Scientific Inc.)

Principle

The PS affinity method1), Fujifilm Wako’s proprietary EV isolation technique, utilizes the Tim4 protein, which specifically binds to phosphatidylserine (PS) present on the surface of EVs. The high specificity of the PS-Tim4 interaction, coupled with the gentle elution by a chelating agent, enables the isolation of high-purity EVs in their intact state.

  • Capture

    03239_img01.png
  • Elution

    03239_img02.png

Protocol

Isolation and purification of EVs using KingFisher™ Flex
(when performing the affinity reaction and elution in a single run)

Sample
pretreatment
[Manual]
Step
01
Sample pretreatment
Centrifuge the samples to precipitate impurities and collect the supernatants.
Buffer
preparation
[Manual]
Step
02
Buffer preparation
Prepare the EV Washing Buffer (1x) and EV Elution Buffer (1x).
Plate
preparation
[Manual]
Step
03
Sample preparation
Dispense the samples into 1.5 mL microtubes and add EV Binding Enhancer.
Step
04
Plate preparation
Prepare each of the following seven types of plates.
Plate name (example) Prepare
(1) Tip1 Place the tip comb in a 96 deep-well plate.
(2) DWP1_Beads Add 60 μL of EV Capture Magnetic Beads and 940 μL of EV Washing Buffer (1x) to the designated wells.
(3) DWP2_sample Add 1 mL of samples to the same well positions as in “(2) DWP1_Beads”.
(4) DWP3_Washing Add 1 mL of EV Washing Buffer (1x) to the same well positions as in “(2) DWP1_Beads”.
(5) DWP4_Washing
(6) DWP5_Washing
(7) DWP6_Elution Add 100 μL of EV Elution Buffer (1x) to the same well positions as in “(2) DWP1_Beads”.
EV isolation
and purification
[Automated]
Step
05
Starting the Device and Program
Launch the KingFisher™ Flex and select the pre-set protocol.
Step
06
Initiating the Processing Program
Place the plates and tips in their designated positions and start the processing program.
Step
07
Collecting the Plates and Tips
Retrieve the plates and tips from the device. The plate labeled “DWP6_Elution” contains the isolated EVs.


Note: To potentially reduce the carryover of impurities from the samples, consider performing the affinity reaction and elution as separate programs, using a new tip comb for elution. For more details, please refer to the instruction manual.

Data

Performance Data

Particle count comparison with the manual kit by NTA

EVs were isolated and purified from various samples (serum, heparin plasma, urine, and COLO 201 cell culture supernatant) using the MagCapture™ EV Isolation Kit PS for HTS (Auto) or MagCapture™ Exosome Isolation Kit PS Ver.2 (Manual). The number of EV particles was quantified by Nanoparticle Tracking Analysis (NTA).

03239_img03.png

[Result]
The MagCapture™ EV Isolation Kit PS for HTS yielded a comparable number of particles to those obtained with the manual kit.

Comparison of EV recovery with the manual kit as measured by ELISA

EVs were isolated and purified from various samples (serum, heparin plasma, urine, and COLO 201 cell culture supernatant) using the MagCapture™ EV Isolation Kit PS for HTS (Auto) or MagCapture™ Exosome Isolation Kit PS Ver.2 (Manual). EV recovery was measured using the PS Capture™ Exosome ELISA Kit (Streptavidin HRP) (Code No. 298-80601).

03239_img04.png
03239_img05.png

[Result]
The rate of recovery achieved using the MagCapture™ EV Isolation Kit PS for HTS was comparable to the manual kit.

Comparison with the manual kit using proteomics analysis

EVs were isolated and purified using the MagCapture™ EV Isolation Kit PS for HTS (Automatic/Automated) or MagCapture™ Exosome Isolation Kit PS Ver.2 (Manual). Proteomic analysis was performed on the resulting EV solutions.

(1) Identified protein species

03239_img06.png

[Result]
The number of proteins identified across four trials was consistently higher with the MagCapture™ EV Isolation Kit PS for HTS compared to the manual kit, suggesting higher reproducibility.

(2) Amount of EV marker proteins

03239_img07.png

[Result]
There was no significant difference in the amount of EV marker proteins in EVs isolated using either the MagCapture™ EV Isolation Kit PS for HTS or the manual kit, indicating that automation did not affect the yield of EVs.

(3) Amount of a non-EV marker protein (albumin)

03239_img08.png

[Result]
The amount of non-EV marker albumin was lower with the MagCapture™ EV Isolation Kit PS for HTS compared to the manual kit, indicating fewer impurities in recovered EVs.

Reference

FAQ

About kit usage

What reagents, instruments, and equipment are required for the EV purification using this kit?

The reagents, instruments, and equipment required for the use of this kit are listed below. (*: Check the instruction manual)


-Reagents-

  • EV Blocking Reagents "EV-Save™ Series"*
    - EV-Save™ Extracellular Vesicle Blocking Reagent (Product Number: 058-09261
    - EV-Save™ Extracellular Vesicle Blocking Reagent for in vivo(Product Number: 050-09461
  • Ultrapure water


-Instruments and Equipment-

  • Centrifuge (Max>10,000×g)
  • Vortex mixer
  • Tabletop centrifuge
  • Micropipette
  • Pipette tip
  • KingFisher™ Flex (Thermo Fisher Scientific Inc.)
  • Deep well, Tip Comb, or Tip plate for KingFisher™ Flex or Prest
    Please select the appropriate product from the following according to the sample volume.
    - The sample volume: <1,000 μL
    KingFisher™ Plastics for 96 deep-well format (Thermo Fisher Scientific Inc., Product Number: 97002820)
    - The sample volume: >1,000 μL
    KingFisher™ Plastics for 24 deep-well format (Thermo Fisher Scientific Inc., Product Number: 97002610)
  • 1.5 mL microtube*
  • 15 mL/50 mL centrifuge tube*
  • Centrifugal Ultra Concentration Unit*
    - VIVASPIN 6, MWCO 100,000, PES (Sartorius, Product Number: VS0641)
    - VIVASPIN 20, MWCO 100,000, PES (Sartorius, Product Number: VS2041)
  • Centrifugal Ultra Filter Unit*
    - Ultrafree®-MC, GV 0.22 μm pore size, sterile (Millipore, Product Number: UFC30GV0S)
    - Ultrafree®-MC, GV 0.45 μm pore size, sterile (Millipore, Product Number: UFC30HV00)

About sample

Can I use EDTA plasma or citrate plasma as a sample?
In the case of EDTA and citrated plasma, the anticoagulant contained in the sample inhibits the binding of EVs to Exosome Capture Magnetic Beads. Therefore, adjust the heparin sodium solution just before the affinity reaction, add it to the centrifuged sample, and proceed to the purification step (For more details, please see instruction manual.)

About commercial or for-profit purposes

Can I use this product for commercial or for-profit purposes?
Please use this product for research purposes only. If you wish to use it for commercial or for-profit purposes, please contact Fujifilm Wako at wkuslabchem@fujifilm.com.

Alias

  • MagCapture™ Exosome Isolation Kit PS for HTS

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.