HPLC Column for Environment Analysis
Wakopak® Wakosil® DNPH, Wakopak® Wakosil® DNPH-Ⅱ
These are columns for the HPLC analysis of aldehydes and ketones in the atmosphere. These special columns are optimized for the simultaneous analysis of 2,4-dinitrophenylhydrazone (DNPH)-derivatized aldehydes and ketones. Aldehydes are subject to regulation and measurement as hazardous air pollutants under the Air Pollution Control Act, Offensive Odor Control Law, etc.
Wakopak® Wakosil® DNPH can separate n- and iso-butyraldehydes, which are difficult to separate with general HPLC columns. It can analyze the same components as those analyzed by GC.
Wakopak® Wakosil® DNPH-II can separate 15 components regulated by the US EPA within 20 minutes.
Example of analysis of 16 DNPH aldehydes
Wakopak® Wakosil® DNPH
n- and iso-butyraldehydes can be separated by HPLC.
Column | :Wakopak® Wakosil® DNPH (4.6 mm x 250 mm) | Sample: | 1) Formaldehyde-2,4-DNPH 2) Acetaldehyde-2,4-DNPH 3) Propionaldehyde-2,4-DNPH 4) Acrolein-2,4-DNPH 5) Acetone-2,4-DNPH 6) iso-Butyraldehyde-2,4-DNPH 7) n-Butyraldehyde-2,4-DNPH 8) Crotonaldehyde-2,4-DNPH 9) iso-Valeraldehyde-2,4-DNPH 10) n-Valeraldehyde-2,4-DNPH 11) Benzaldehyde-2,4-DNPH 12) Hexaldehyde-2,4-DNPH 13) o-Tolualdehyde-2,4-DNPH 14) m-Tolualdehyde-2,4-DNPH 15) p-Tolualdehyde-2,4-DNPH 16) 2,5-Dimethylbenzaldehyde-2,4-DNPH each 0.625 µg/mL (as aldehyde, ketone) |
Eluent | :A) Wakosil® DNPH Eluent A B) Wakosil® DNPH Eluent B 0 - 16 min. B 10 % 16 - 35 min. B 10 - 90 % 35 - 45 min. B 90 % |
||
Flow Rate | :0.6 mL/min. at 37 ℃ | ||
Detection | :UV 360 nm, 0.016 AUFS |
Analysis of 15 DNPH aldehydes (rapid analysis)
Wakopak® Wakosil® DNPH-II
1. Blank
One Presep®-C DNPH cartridge eluted with acetonitrile and diluted to 5 mL.
2. Example of analysis of indoor air sample
30 L of air in the laboratory sampled at a flow rate of 0.5 L/min using Presep®-C DNPH and eluted in the same manner as described above.
3. Reference standard
Chromatogram of the reference standard of 15 DNPH-derivatized aldehydes
-
Column :Wakopak® Wakosil® DNPH-II (4.6 mm x 150 mm) Eluent :A) Wakosil® DNPH-Ⅱ Eluent A
B)Wakosil® DNPH-Ⅱ Eluent B
0 - 10 min B conc. 0-100 %
10 - 16 min B conc. 100 %Flow Rate :1.0 mL/min. at 35 ℃ Detection :UV 360 nm Injection Volume :10 µL -
Sample: 1) Formaldehyde-2,4-DNPH
2) Acetaldehyde-2,4-DNPH
3) Acetone-2,4-DNPH
4) Acrolein-2,4-DNPH
5) Propionaldehyde-2,4-DNPH
6) Crotonaldehyde-2,4-DNPH
7) n-,iso-Butyraldehyde-2,4-DNPH
8) Benzaldehyde-2,4-DNPH
9) iso-Valeraldehyde-2,4-DNPH
10) n-Valeraldehyde-2,4-DNPH
11) o-Tolualdehyde-2,4-DNPH
12) m-Tolualdehyde-2,4-DNPH
13) p-Tolualdehyde-2,4-DNPH
14) Hexaldehyde-2,4-DNPH
15) 2,5-Dimethylbenzaldehyde-2,4-DNPH
each 0.1 μg/mL (as aldehyde,ketone)
Product List
- Open All
- Close All
Column for HPLC
DNPH Eluent
Mixture Standard Solution
Solid-phase extraction column for pretreatment
Solvent
For research use or further manufacturing use only. Not for use in diagnostic procedures.
Product content may differ from the actual image due to minor specification changes etc.
If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.