C18 column, analytical validation supported

Wakopak® Wakosil®-Ⅱ 3C18 HG, RS, AR

  • Completely porous, spherical packing agent with a diameter of 3 μm.
  • The number of theoretical plates and resolution are improved compared with the 5 μm packing agent (≥100,000 theoretical plates/m). Therefore, it is possible to shorten the column.
  • Line-up three types, HG, RS, and AR, as in the case of the 5C18 Series, and facilitate the migration of analytical conditions.
  • Solvent usage is reduced, thus economizing on resources.
  • Sample microsizing and high-sensitivity analysis are possible.
  • Can be used in LC/MS.

Applications

Investigation of column shortening (analysis of preservative (paraben))

  • 01080_img01.png
  • Sample






    Eluent
    Flow Rate
    Detection
    :1)Methyl p-Hydroxybenzoate
     2)Ethyl p-Hydroxybenzoate
     3)Isopropyl p-Hydroxybenzoate
     4)n-Propyl p-Hydroxybenzoate
     5)sec-Butyl p-Hydroxybenzoate
     6)Isobutyl p-Hydroxybenzoate
     7)n-Butyl p-Hydroxybenzoate
    :CH3OH/5 mM Citrate buffer(pH4.0)
    :0.8 mL/min. at 40℃
    :UV 270 nm

 

Features of semi-micro columns

Semi-micro columns with an inside diameter of 1.0 to 2.0 mm can be used at a lower flow rate than a general-purpose column to reduce the amount of solvent used. And semi-micro columns are suitable for use in LC/MS. In addition, analysis is possible with a small amount of sample by improved sensitivity. For example, when columns with inside diameters of 2.0 mm and 4.6 mm are compared, the ratio of cross-sectional areas is approximately 1/5; therefore, the sensitivity is increased by a factor of approximately 5, and the amount of solvent consumed is approximately 1/5.

 

Data comparison between 3 mm and 4.6 mm internal diameter columns

A general-purpose column with an internal diameter of 3.0 mm achieves a solvent consumption of approximately 1/2 and approximately double the sensitivity with the equipment available presently, in contrast to the equipment responding to the semi-micro column with the detector cell volume.

 

Example of shortened analysis time (Veterinary Drug Mixture Standard Solution PL-2-1: 24 species mixture, 20 μg/mL each of methanol solution)

Column: Wakopak® Wakosil®-Ⅱ 3C18 HG

positive mode 23 ingredients 0.1 ppm

01080_img02.png

 

negative mode 1 ingredients 0.1 ppm

01080_img03.png

 

HPLC conditionss

Column
Eluent
:Wakopak® Wakosil®-Ⅱ 3C18 HG
:A)0.1% HCOOH in H2O*
 B)0.1% HCOOH in CH3CN**
Time Program
Column size
3.0 x 150 mm 2.0 x 100 mm B conc.
0-35 min. 0-10.5 min. 1-100%
35-40 min. 10.5-12 min. 100%
40-50 min. 12-22 min. 1%
Flow Rate
Injection Vol.
:0.2 mL/min. at 40℃
:0.1 ppm, 4 μL (3.0 x 150 mm), 3 μL (2.0 x 100 mm)
*

**
Formic Acid (abt. 99%) for LC/MS (Code No. 067-04531)
Ultrapure Water for LC/MS (Code No. 214-01301)
0.1 vol% Formic Acid-Acetonitrile (Code No. 062-04721)

 

MS/MS conditions

ESI, MRM

Ion Spray Voltage
Temperature
Curtain Gas
Collision Gas
Ion Source Gas 1
Ion Source Gas 2
System
:5500 V (pos), -4500 V (neg)
:400℃ (po9), 500℃ (neg)
:20
:6
:50
:80
:3200Q TRAP (ABI)

 

Veterinary Drug Mixture Standard Solution PL-2-1: 24 species mixture

Peak
No.
Analyte Peak Name Analyte Mass Ranges
(amu)
Analyte Retention Time
(min)
Precursor Product Mode 3 x 150 mm 2 x 100 mm
1 5-Propylsulfonyl-1H-benzimidazole-2-amine 240.1 133.2 + 11.2 4.7
2 Levamisole 207.1 91.2 + 11.3 4.7
3 Thiabendazole 202.1 175.1 + 11.8 4.9
4 Trimethoprim 291.1 230.3 + 12.0 4.9
5 Sulfadiazine 251.1 92.2 + 12.3 5.0
6 Ormetoprim 275.2 123.1 + 12.5 5.1
7 Sulfathiazole 256.0 156.0 + 12.8 5.2
8 Sulfapyridine 250.0 156.2 + 13.2 5.3
9 Sulfamerazine 265.1 92.2 + 13.8 5.5
10 Thiamphenicol 355.9 308.0 + 14.4 5.7
11 Sulfadimidine 279.1 92.1 + 15.0 5.9
12 Sulfamethoxypyridiazine 281.1 156.1 + 15.0 5.9
13 Sulfamonomethoxine 281.1 156.1 + 16.1 6.2
14 Sulfachlorpyridazine 286.1 157.1 + 16.7 6.4
15 Sulfamethoxazole 254.0 156.0 + 17.5 6.6
16 Sulfadoxine 311.1 156.1 + 17.4 6.6
17 Ethopabate 238.2 136.0 + 19.3 7.2
18 Sulfaquinoxaline 301.0 156.2 + 19.4 7.2
19 Sulfadimethoxine 311.1 156.2 + 19.4 7.2
20 Sulfanitran 336.1 134.1 + 21.9 7.9
21 β-Trenbolone 271.2 165.3 + 23.2 8.3
22 α-Trenbolone 271.2 165.2 + 23.7 8.5
23 Melengestrol Acetate 397.2 279.4 + 31.3 10.7
1 Zeranol 321.1 277.2 - 24.2 8.7

Veterinary Drug Mixture Standard Solution PL-2-1 (Code No. 227-01691)

Product List

  • Open All
  • Close All

Wakopak® Wakosil®-Ⅱ 3C18 HG

ODS column for reverse-phase chromatography, compatible with analytical validation.

Wakopak® Wakosil®-Ⅱ 3C18 RS

ODS column for reverse-phase chromatography, compatible with analytical validation.

Wakopak® Wakosil®-Ⅱ 3C18 AR

ODS column for reverse-phase chromatography, compatible with analytical validation.

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.

+49-2131-311-271

Reception hours: Mon-Fri 9:00 - 15:00 (CET)For other hours than the above, please contact us via the inquiry form.