Column for silica gel hydrophilic interaction chromatography (HILIC)

Wakopak® Wakosil®-Ⅱ 5SIL-AQ

Wakosil®-II 5SIL-AQ is a high-purity silica gel packing agent for HPLC.
Superior analysis of highly polar substances is possible, especially basic substances with low retention that are difficult to analyze with common ODS packing agents, further broadening the scope of HPLC analysis.

Features

  • Excellent analysis of highly polar and basic compounds
  • Use of high-purity silica gel: to suppress the influence of metal impurities
  • Easier to apply to LC/MS analysis: Analysis conditions that use high concentration of organic solvent, and do not use ion-pair reagents can be set.

Applications

Analysis of nucleosides

  • 01064_image01.png
  • Column
    Eluent
    Flow Rate
    Detection
    Injection
    :Wakopak® Wakosil®-Ⅱ 5SIL-AQ (4.6 mm×250 mm)
    :CH3CN/0.1M HCOONH4 (pH 3.0) = 85/15 (v/v)
    :1.0 mL/min. at 40℃
    :UV 260 nm
    :each 0.1 mg/mL (H2O), 10 μL

 

Analysis of tricyclic antidepressant (imipramine)

  • 01064_image02.png
  • Column
    Eluent
    Flow Rate
    Detection
    Injection
    :Wakopak® Wakosil®-Ⅱ 5SIL-AQ (4.6 mm×250 mm)
    :CH3CN/0.1M HCOONH4 (pH 3.0) = 85/15 (v/v)
    :1.0 mL/min. at 40℃
    :UV 254 nm
    :each 0.2 mg/mL (EtOH), 10 μL

 

Analysis of acid substances (ascorbic acid)

  • 01064_image03.png
  • Column
    Eluent
    Flow Rate
    Detection
    Injection
    :Wakopak® Wakosil®-Ⅱ 5SIL-AQ (4.6 mm×250 mm)
    :CH3CN/H2O/H3PO4=97/2/1(v/v/v)
    :1.0 mL/min. at 40℃
    :UV 210 nm
    :each 1.0 mg/mL (90%CH3CN), 5 μL

 

Analysis of crude drug ingredients (1)

  • 01064_image04.png
  • Column
    Eluent
    Flow Rate
    Detection
    Injection
    :Wakopak® Wakosil®-Ⅱ 5SIL-AQ (4.6 mm×250 mm)
    :CH3CN/0.1M HCOONH4 (pH 3.0) = 95/5 (v/v)
    :1.0 mL/min. at 40℃
    :UV 345 nm
    :each 0.2 mg/mL (90% CH3CN), 5 μL

 

Analysis of crude drug ingredients (2)

  • 01064_image05.png
  • Column
    Eluent
    Flow Rate
    Detection
    Injection
    :Wakopak® Wakosil®-Ⅱ 5SIL-AQ (4.6 mm×250 mm)
    :CH3CN/0.1M HCOONH4 (pH 3.0) = 85/15 (v/v)
    :1.0 mL/min. at 40℃
    :UV 254 nm
    :each 1 mg/mL (CH3CN), 10 μL

 

Analysis of crude drug ingredients (3)

  • 01064_image06.png
  • Column
    Eluent
    Flow Rate
    Detection
    Injection
    :Wakopak® Wakosil-Ⅱ® 5SIL-AQ (4.6 mm×250 mm)
    :CH3CN/0.1M HCOONH4 (pH 3.0)= 80/20 (v/v)
    :1.0 mL/min. at 35℃
    :UV 210 nm
    :each 0.5 mg/mL (CH3CN), 5 μL

Product List

  • Open All
  • Close All

Wakopak® Wakosil®-Ⅱ 5SIL-AQ

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.

The prices are list prices in Japan.Please contact your local distributor for your retail price in your region.

Please contact us via the inquiry form.