It has been added to the cart.

It has been added to the comparison table.

Phthalaldehyde

for Biochemistry
Specification Assay :
99.0+% (cGC)
Manufacturer :
FUJIFILM Wako Pure Chemical Corporation
Storage Condition :
Keep at 2-10 degrees C.
CAS RN® :
643-79-8
Molecular Formula :
C6H4(CHO)2
Molecular Weight :
134.13
  • Structural Formula
  • Label
  • Packing
Comparison
Product Number
Package Size
Price
Inventory
Distributor
161-09261
Barcode No
4987481313392
1g
Inquire

In stock in Japan

Distributor
167-09263
Barcode No
4987481313415
5g
Inquire

In stock in Japan

Distributor
169-09262
Barcode No
4987481313408
25g
Inquire

In stock in Japan

Distributor
165-09264
Barcode No
4987481313422
100g
Inquire

In stock in Japan

Document

Product Specification Sheet
Spectral Data
Certificate of Analysis
Calibration Certificate

Application

Overview / Applications

Outline This product is for research use only. Do not administer it to human.
Fluorescence analysis is most suitable for microanalysis by, for example, HPLC, because it is more sensitive than the ninhydrin method.The detection limit is 5 pmol or less. It is 30 pmol for Cys. It is 100 pmol for Pro using the NaClO method.Sympathetic catecholamine metabolism plays a key role in cardiovascular diseases (such as ischemic diseases, heart failure and hypertension). Catecholamine is analyzed by high performance liquid chromatography and detected by the nynhydrin coloring method, fluorescence method using OPA and the electrochemical method (ECD).Thiol is required for reaction.
Spectrofluorimetry using o-phthalaldehyde (OPA method) is the most sensitive method of detecting primary amines including catecholamine, polyamine, amino acids and peptides. The product has very high purity and particularly low fluorescence background.
Instructions React at pH 8.0, 50 degrees C for 0.5 min.

Property

Appearance Pale yellow - yellow, crystals - crystalline powder
Melting Point 54 - 58 degrees C
Boiling Point 83 - 84 degrees C

Manufacturer Information

Alias

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.

+49-2131-311-271

Reception hours: Mon-Fri 9:00 - 15:00 (CET)For other hours than the above, please contact us via the inquiry form.