Reagent for Ion-Pair Chromatography

Ion-pair chromatography is a method to analyze a sample containing electrolytes by reverse-phase chromatography. In this method, excess counter ions are added to the mobile phase, and the sample is separated and analyzed as an undissociated molecule.

Low UV Type Ion-Pair Reagent


  • The low UV type ion-pair reagent has minimal UV absorption in the short wavelength region. In addition, it is easily dissolved in the mobile phase because it is the solution.

    Use quaternary alkyl ammonium salts for compounds with an acidic functional group and alkyl sulfonates for compounds with a basic functional group.

  • Specification (Low UV Type)
    (ex. 0.5 mol/L Tetrabutylammonium Dihydrogenphosphate Solution)
    Appearance Colorless clear liquid
    Absorbance 200 nm: max. 0.50 254 nm: max. 0.15
    210 nm: max. 0.30 300 nm: max. 0.10
    240 nm: max. 0.15 350 nm: max. 0.05
    Fluorescence Test to pass test
    Content 0.45-0.55 mol/L

Comparison of Absorbance

  • Tetra-n-butylammonium Phosphate Sol. (0.25 mol/L)
    00990_img01R.png
  • 1-Hexanesulfonic Acid Sodium Salt Sol. (0.25 mol/L)
    00990_img02R.png

Comparison between General Ion-Pair Reagents and Low UV Type Ion-Pair Reagent in the Low-Wavelength Region


  • 00990_img06.png
    (Fig.1)

  • 00990_img07.png
    (Fig.2)
  • Analysis Conditions
    Column: Wakosil®-Ⅱ 3C18HG (4.6 φ × 50 mm)
    Eluent : (Fig.1) KH2PO4 (819 mg) + NaH2PO4 (714 mg) + 0.5 M Tetra-n-butylammonium Phosphate Sol. (10 mL) in 1,000 mL H2O
    (Fig.2) KH2PO4 (819 mg) + NaH2PO4 (714 mg) + 0.5 M Tetra-n-butylammonium Phosphate Sol. (Low UV Type 10 mL) in 1,000 mL H2O
    Flow rate:
    Detector:
    Sample:
    1.0 mL/min. at 40℃
    UV 205 nm, 210 nm
    Potassium Bromaide in H2O

Reagent for Ion-Pair Chromatography

00990_img05.png

This product is assured of absorbance, etc. for use in ion-pair chromatography.

The alkyl sulfonate is a powder type, and the quaternary alkyl ammonium salts is solution.

Reference: Column washing after using ion-pair reagent

When using quaternary alkyl ammonium salts

For use of the mobile phase spiked with quaternary alkyl ammonium salts such as tetrabutylammonium hydroxide, immediately flowing water for column cleaning after use may cause the liquid in the column to become alkaline and deteriorate the silica gel packing agent.

In this case, wash with 0.1% phosphoric acid solution and replace with distilled water for HPLC and the storage solvent in this order.

The passed volume of each solvent is about 10 times the column volume.

Use of alkyl sulfonate

For column washing after using the mobile phase spiked with alkyl sulfonate, it is effective to wash not only with distilled water for HPLC but also with a solution prepared by mixing an equal volume of organic solvents (e.g., methanol, acetonitrile).

Then, replace with distilled water for HPLC and storage solvent, but attention should be paid to an increase in the column pressure.

The passed volume of each solvent is about 15 to 20 times the column volume.

Product List

  • Open All
  • Close All

Reagent for Ion-pair Chromatography - Low UV Type

Reagent for Ion-pair Chromatography

Related Product List

  • Open All
  • Close All

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.

+49-2131-311-271

Reception hours: Mon-Fri 9:00 - 15:00 (CET)For other hours than the above, please contact us via the inquiry form.