It has been added to the cart.

It has been added to the comparison table.

Human Chromogranin A ELISA Kit Wako

for Immunochemistry
Manufacturer :
FUJIFILM Wako Pure Chemical Corporation
Storage Condition :
Keep at 2-10 degrees C.
  • Structural Formula
  • Label
  • Packing
Comparison
Product Number
Package Size
Price
Inventory
Distributor
292-85501
Barcode No
4548995094988
96Tests
Inquire

Document

Package Insert
Spectral Data
Certificate of Analysis
Calibration Certificate

Kit component

Kit Component

Antibody-coated Plate 1 plate
Chromogranin A Standard 1 vial
Biotin-conjugated Chromogranin A 1 vial
Anti-Human Chromogranin A Antibody 1 vial
Peroxidase-conjugated Streptavidin Solution 12 mL
Substrate Buffer 25 mL
OPD Tablet 2 tablets
Stop Solution 12 mL
Buffer (5×) 12 mL
Wash Solution (20×) 50 mL
Plate Seal 3 sheets

Product Information

Chromogranin A (CgA) is an acidic glycoprotein that coexists and is co-released with catecholamine in the adrenal medulla and sympathetic nerve endings. CgA is thought to reflect secretion of catecholamine and is used as an activity index for the sympathetic-adrenal-medullary (SAM) axis, a stress-response pathway. It is also used as a tumor marker for patients with pheochromocytomas or neuroendocrine tumors, who have high levels of CgA in the blood.

CgA is also present in saliva, is synthesized in the submandibular gland, and is released into saliva in response to autonomic stimulation. Previous studies have reported that saliva CgA levels increase in response to stress1) 2), and thus, it is particularly useful as an excellent noninvasive biomarker for mental stress.

Human Chromogranin A ELISA Kit Wako is a competitive ELISA kit for assaying CgA in human saliva and plasma.

  • Kit Performance

    The range of the calibration curve 0.14 - 33.33 pmol/mL
    Assay target Chromogranin A
    Sample Human Saliva/Plasma
    The sample amount required 50 µL (n=2)
    Assay time O/N+2.5 hours
    Detection method Colorimetry
    Within assay variation CV < 14%
    Between assay variation CV < 16%
  • Example of Calibration Curve

    04436113_img01R.png

Data

Spiked recovery test

Sample Amount spiked (pmol/mL) Measured value (pmol/mL) Recovery rate (%)
Plasma 0 0.54 -
0.25 0.86 108.86
1 1.93 125.32
4 6.58 144.93
Saliva 0 0.47 -
0.25 0.81 112.50
1 1.40 95.24
4 3.66 81.88

References

FAQ

About sample

How should I store samples?
Plasma and saliva should be measured immediately after collection. If measurement cannot be performed immediately, divide the sample into small aliquots and store frozen at -30°C or below. Avoid repeated freezing and thawing of samples.
Which anticoagulant should I use for blood samples?
EDTA plasma, heparin plasma, or citrate plasma can be used. The same anticoagulant should be used throughout the measurement.
How should I pretreat highly viscous saliva samples?
Highly viscous saliva may not provide a correct measurement value. Precipitate mucin, etc. by centrifugation and use the supernatant.

About analyte

What is the degree of cross-reactivity with chromogranin A processing products?
It shows 100% cross-reactivity with the synthetic N-terminal fragment of parastatin [human CgA (356-374)]. It does not cross-react with pancreastatin or β-granin at all.
Fujifilm Wako have not checked cross-reactivity with vasostatin or catestatin, but based on the antibody recognition site (human CgA344-374) of the product, its cross-reactivity with vasostatin is expected to be very low, while cross-reactivity with catestatin is possible.
What is the degree of cross-reactivity with non-human species?
It shows 70% cross-reactivity with rat chromogranin A.
Fujifilm Wako have not checked cross-reactivity with other species.

About the kit

What is the origin of the standard?
The origin is synthetic human chromogranin A (344-374).
Can I divide plates?
Since the plate in this kit are separable and each row (8 wells) is detachable, divided use of the kit is possible.

About kit usage

What reagents, instruments, and equipment are required for measurement with this kit?
The following reagents, instruments, and equipment are required to use this kit:
  • Micropipettes and disposable tips (25 to 1,000μL) (8- or 12- channel pipettes are recommended.)
  • Microplate reader which can read extinction 2.5 at 490 nm
  • Microplate shaker or conventional shaker
  • Test tubes for dilution of standard solutions and samples (glass or polypropylene)
  • Microplate washer (For manual operation, a continuous dispenser, needle dispenser, and an aspirator or vacuum pump are recommended.)
  • Graduated cylinder (1,000 mL)
  • Distilled or deionized water

Overview / Applications

Property

Manufacturer Information

Alias

For research use or further manufacturing use only. Not for use in diagnostic procedures.

Product content may differ from the actual image due to minor specification changes etc.

If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.

+49-2131-311-271

Reception hours: Mon-Fri 9:00 - 15:00 (CET)For other hours than the above, please contact us via the inquiry form.