SARS-CoV-2 Real-Time RT-PCR Detection Kit(N gene)
- for Genetic Research
- Manufacturer :
- FUJIFILM Wako Pure Chemical Corporation
- Storage Condition :
- Keep at -20 degrees C.
- Structural Formula
- Label
- Packing
- SDS
Document
Kit component
Kit components (for 200 reactions)
5×Reaction Buffer | 800 μL |
---|---|
2mmol/L dNTPs | 800 μL |
50mmol/L Manganese(II) Acetate | 200 μL |
Hot Start Reverse Transcription DNA Polymerase | 50 μL |
Distilled Water, Nuclease-free | 590 μL |
Fw and Rv Primers 1 | 100 μL |
TaqManⓇ Probe 1 | 40 μL |
Fw and Rv Primers 2 | 100 μL |
TaqManⓇ Probe 2 | 40 μL |
Positive Control RNA, N gene | 1,000 μL |
*A ROX for passive reference dye is not supplied in this kit. Please prepare it as needed. TaqManⓇ is registered trademark by Roche Diagnostics K.K. | - |
Materials required but not provided
Real-Time PCR instrument | - |
---|---|
Microcentrifuge | - |
Micro pipette and nuclease-free pipette tips | - |
Nuclease-free 1.5mL tubes(e.g. Micro tube 1.5ml DNA LowBind, Sarstedt) | - |
Real-time PCR plates and plate films or real-time PCR tubes and caps. | - |
TaqMan® is registered trademark by Roche Diagnostics K.K. | - |
Overview
Product description
SARS-CoV-2 Real-Time RT-PCR Detection Kits a reagent system, based on an one-step real-time PCR method, for the qualitative detection of SARS-CoV-2-derived RNA. The highly active enzyme applied in the kit allows high-speed real-time PCR and it plays dual roles as reverse transcriptase and DNA polymerase.
The primer/probe No.1 and 2 are designed to hybridize to N(Nucleocapsid) gene and labeled with the FAM.
Key Features
- RT-PCR only for 45 minutes
- Inhibiting non-specific amplification by hot start PCR
- Including positive controls
Two targets at N gene
Protocol flow
-
- Prepare extracted RNA from SARS-CoV-2.
- Dilute Positive Control RNA with water.
- Prepare PCR master mix.
- Apply PCR master mix and RNA into real-time PCR plate or tube.
- Run a real-time PCR instrument.
Probe Reporter TaqMan® Probe 1 FAM TaqMan® Probe 2 FAM
Example of arrangement of applying samples in 96-well plate
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9-12 | |
A | |||||||||
B | P | S1 & No.1 | S2 & No.1 | S3 & No.1 | S4 & No.1 | S5 & No.1 | |||
C | N | S1 & No.2 | S2 & No.2 | S3 & No.2 | S4 & No.2 | S5 & No.2 | |||
D | |||||||||
E | |||||||||
F | |||||||||
G | |||||||||
H |
S:Sample
No.1:Fw & Rv Primers 1, TaqMan® Probe 1
No.2:Fw & Rv Primers 2, TaqMan® Probe 2
P : Positive control
N : Negative control
Two wells are used for one sample |
Example applications
Positive control RNA, N=2
Positive control RNA, N=2
Standard Curve
Manufacturer Information
Alias
For research use or further manufacturing use only. Not for use in diagnostic procedures.
Product content may differ from the actual image due to minor specification changes etc.
If the revision of product standards and packaging standards has been made, there is a case where the actual product specifications and images are different.